# SDR SWAA2021090705863

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: August 10, 2021
- Submitted: September 7, 2021
- Operation: Air carrier
- Aircraft: N755SA
- Make and model: Boeing 737-7H4
- Registry model: [Boeing 737-7H4](https://openairdocs.org/model/boeing-737-7h4) (OpenAirDocs)
- Aircraft serial: 27871
- Aircraft time: 74,723 hours, 44,099 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Support
- Condition: Corroded
- Location: Bs 500-500c
- Stage of operation: IN
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWAA2021090705863

## Discrepancy

CORROSION ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500 - BS500C LBL24 WL156. ; / [01] EVALUATED CORROSION; FOUND 0.015 REMOVED FROM ORIGINAL 0.040 IN 1'X60' AREA FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DIAL DEPTH GAUGE ATS 2472 S/N UNKNOWN; [02] VERIFIED EVALUATED CORROSION; FOUND 0.015 REMOVED FROM ORIGINAL 0.040 IN 1'X60' AREA FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DIAL DEPTH GAUGE ATS 2472 S/N UNKNOWN; [03] REMOVED FLOOR TO SIDEWALL SUPPORT BS 396-500D RBL 24; WL 156 PER SRM 51-40-02-0G-0.; [04] SHOULD READ LBL 24; NOT RBL.; [05] FABRICATED NEW L/H FLOOR TO SIDEWALL SUPPORT BS 396 TO 500D AND SPLICE DOUBLER FROM EXTRUSION BAC1496-444#7075 T62 CLAD LOT# 1466234-1 PER SRM 51-40-05-0G-0; SRM 53-00-53-2R-5; DWG 143A7501; DWG 143A7500; [06] VERIFIED STEP 5; [07] VERIFIED CORRECTIVE ACTION STEP 5<BR>OK TO APPLY CHEMICAL CONVERSION AND PRIMER; [11] INSTALLED SPLICE DOUBLER PER SRM 53-00-53-2R-5 AND DWG 143A7501; [12] CERTIFIED STEP 11; [13] RII INSPECTED GOOD INSTALLATION OF SPLICE DOUBLER PER SRM 53-00-53-2R-5 AND DWG 143A7501.; [14] SRM SPLICE REPAIR LOCATION IS AT BS 480+8'; [15] VERIFIED LOCATION OF SRM SPLICE REPAIR; [16] VERIFIED CORRECTIVE ACTION ITEMS 14 AND 15; [17] OK TO INSTALL L/H FLOOR TO SIDEWALL SUPPORT; [18] OK TO INSTALL; [19] INSTALLED FCB NEW FLOOR TO SIDEWALL SUPPORT AT BS396 - BS500D; LBL24; WL156 PER SRM 51-40-020G-0 AND DWG 143A7500

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.