# SDR SWAA2022092046638

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: August 27, 2022
- Submitted: September 20, 2022
- Operation: Air carrier
- Aircraft: [N7878A](https://openairdocs.org/aircraft/N7878A), registered now
- Make and model: Boeing 737
- Aircraft serial: 34320
- Aircraft time: 52,141 hours, 25,914 cycles
- System (JASC): [5321 · Fuselage Floor Panel](https://openairdocs.org/jasc/5321)
- Part: Floor Panel
- Part number: 242QF
- Condition: Pulled
- Location: Cabin Floor
- Stage of operation: IN
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWAA2022092046638

## Discrepancy

FLOOR PANEL 242QF UPPER SURFACE HAS PULLED STRANDS. / [01] DAMAGE TO PANEL 241QF IS OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4. F. AND NEW PANEL WILL BE FABRICATED FROM NEW STOCK<BR><BR>ROUGHCUT AND DRILLED NEW FLOOR PANEL 241QF IAW SRM 53-00-50-2R-0 AND DWG 146A5810-13. USED NEW PANEL STOCK BMS4-23 TY 11; LOT# 1501450-1;[02] MATERIAL USED IS BMS4-23 TY 2; LOT# 1501450-1 NOT BMS4-23 TY 11; LOT# 1501450-1 AS NOTED IN CORRECTIVE ACTION 1;[03] INSTALLED ALL INSERTS USING BMS5-107 LOT#AK1KP9159K AND CURED USING HEATLAMP AND THERMOMETER ATS2208 CAL DUE DATE 10/2022 THEN PART MARKED PANEL IAW SRM 53-00-50-2R-0 PARA 5S AND DWG 146A5810-13;[04] VERIFIED CORRECTIVE ACTIONS 1-3;[05] UPLOADED CURE SHEET; UPDATED MEASUREMENTS AND VERIFIED COMPLETION OF PANEL FABRICATION;[06] VERIFIED CORRECTIVE ACTION 5<BR><BR>VERIFIED MEASUREMENTS TABLE

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.