# SDR SWAA2023041926191

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: April 11, 2023
- Submitted: April 19, 2023
- Operation: Air carrier
- Aircraft: [N240WN](https://openairdocs.org/aircraft/N240WN), registered now
- Make and model: Boeing 737-7H4
- Registry model: [Boeing 737-7H4](https://openairdocs.org/model/boeing-737-7h4) (OpenAirDocs)
- Aircraft serial: 32503
- Aircraft time: 56,457 hours, 33,866 cycles
- System (JASC): [5321 · Fuselage Floor Panel](https://openairdocs.org/jasc/5321)
- Part: Floor Panel
- Condition: Pulled
- Location: Zn 200 Fus Top
- Stage of operation: IN
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWAA2023041926191

## Discrepancy

DOT A24-3 MID CABIN FLOOR PANEL 231XF HAS PULLED COMPOSITE FIBERS ON UPPER SURFACE.<[01] EVALUATED PANEL 231XF AND FOUND PULLED FIBERS ON UPPER SURFACE. FOUND TO BE REPAIRABLE. IAW B737-700 SRM 53-00-50-2R-1 PAR1A. CLEAN AND PREP. IAW B737-700 SRM 53-00-50-2R-1 PAR 3A;C;E&F. VERIFIED MATERIALS AS: BMS 8-201 (A171808); BMS 9-3 (A164924). IAW B737-700 SRM 53-00-50-2R-1 TABLE 201. NEED OK TO BOND.;[02] VERIFIED STEP 1 AND OK TO BOND;[03] BONDED REPAIR PLIES. IAW B737-700 SRM 53-00-50-2R-1 PAR 3K-M.;[04] REPAIRED AREAS OF PULLED FIBERS ON UPPER SURFACE OF PANEL231XF. IAW B737-700 SRM 53-00-50-2R-1. SRM 53-00-50-2R-0.;[05] VERIFIED STEPS 3-4

---