# SDR SWI2025F01296

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 22, 2025
- Submitted: September 9, 2025
- Operation: Air carrier
- Aircraft: [N896SK](https://openairdocs.org/aircraft/N896SK), registered now
- Make and model: Cndair CL6002D24
- Aircraft serial: 15102
- Aircraft time: 31,664 hours, 24,996 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Floor Support
- Condition: Corroded
- Location: Zone 200
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWI2025F01296

## Discrepancy

RH FLOOR SILL IS CORRODED FS280 Â€“ 319  (C-CHECK RO 09/07/2025)REMOVED AND INSTALLED RH FLOOR SILL BETWEEN FS280.00 - FS319.00. PRESSURE LEAK TEST GOOD. REF - CRJ900 SRM 51-42-06-001-001-A01, CRJ 900 SRM 51-42-13-001-001-A01, CRJ 900 SRM 51-42-21-001-001-A01. AND DWG. NO. SH690-32170 REV. AD COMPLIED WITH 51-900-1002-SKY

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.