# SDR SWIA200211192

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: September 2, 2002
- Submitted: September 6, 2002
- Operation: Air carrier
- Aircraft: [N909SW](https://openairdocs.org/aircraft/N909SW), registered now
- Make and model: Cndair CL6002B19
- Aircraft serial: 7558
- Aircraft time: 2,456 hours, 2,330 cycles
- System (JASC): [2920 · Hydraulic System, Auxiliary](https://openairdocs.org/jasc/2920)
- Part: Hydraulic Line
- Condition: Leaking
- Location: Hyd System
- Stage of operation: AP
- How discovered: O
- Nature of condition: K, J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA200211192

## Discrepancy

HYD PUMP 2B MESSAGE ILLUMINATED ON APPROACH.  HYDRAULIC SYNOPTIC PAGE SHOWED 0 PERCENT FLUID, TEMP 40 DEGREES WITH HYD PSI OF 3000.  REPLACED NR 2 HYD SYSTEM TUBE ASSY, CASE DRAIN AND TUBE ASSY, PUMP PRESS LINE.  SERVICED NR 2 HYD SYSTEM.  NO LEAKS NOTED.  OPS CHECK GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.