# SDR SWIA200211535

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 1, 2002
- Submitted: December 6, 2002
- Operation: Air carrier
- Aircraft: N301YV
- Make and model: Emb EMB-120ER
- Registry model: [EMB EMB-120ER](https://openairdocs.org/model/embraer-emb-120er) (OpenAirDocs)
- Aircraft serial: 120301
- Aircraft time: 16,342 hours, 22,727 cycles
- System (JASC): [2932 · Hydraulic Pressure Sensor](https://openairdocs.org/jasc/2932)
- Part: Pressure Switch
- Condition: Malfunctioned
- Location: Hyd System
- Stage of operation: TO
- How discovered: O
- Nature of condition: J
- Precautionary procedure: C
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA200211535

## Discrepancy

LT HYDRAULIC RESERVOIR LOW PRESSURE LIGHT ILLUMINATED DURING TAKEOFF.  ABORTED THE TAKEOFF.   REMOVED & REPLACED LT HYDRAULIC RESERVOIR LOW PRESSURE SWITCH.  OPS CHECK GOOD.  NO LEAKS NOTED.  PN OFF 120-48659-001  SN OFF 0134.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.