# SDR SWIA200616811

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 30, 2006
- Submitted: November 16, 2006
- Operation: Air carrier
- Aircraft: N562SW
- Make and model: Emb EMB-120
- Registry model: [EMB EMB-120](https://openairdocs.org/model/embraer-emb-120) (OpenAirDocs)
- Aircraft serial: 120336
- Aircraft time: 17,962 hours, 26,200 cycles
- System (JASC): [2460 · DC Power Distribution System](https://openairdocs.org/jasc/2460)
- Part: Relay
- Condition: Malfunctioned
- Location: Cockpit
- Stage of operation: NR
- How discovered: O
- Nature of condition: B
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA200616811

## Discrepancy

CHEMICAL ODOR IN THE FLIGHT DECK MOSTLY FROM RIGHT SIDE.  REPLACED OVERHEATED APU FEEDER PROTECTION RELAY IAW MM 24-37-00.  OPERATIONAL CHECKS GOOD, P/N - 44B258051-002.

---