# SDR SWIA200617592

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 15, 2006
- Submitted: January 2, 2007
- Operation: Air carrier
- Aircraft: N905SW
- Make and model: Cndair CL6002B19
- Aircraft serial: 7437
- Aircraft time: 16,187 hours, 13,558 cycles
- System (JASC): [5315 · Fuselage Main, Floor Beam](https://openairdocs.org/jasc/5315)
- Part: Floorbeam
- Condition: Cracked
- Location: Bs 280
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA200617592

## Discrepancy

FS 280 FLOORBEAM ANGLE AT LBL10 CRACKED AND BOTH OF 280 CLIPS ARE CRACKED LBL10, DISCOVERED DURING C-CHECK INSPECTION.  INSTALLED FABRICATED REPAIR PARTS AND ANGLE AT STA 280 LBL10 PER CRJ200 REO 601R 53-11-138.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.