# SDR SWIA201230095

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 19, 2012
- Submitted: March 21, 2012
- Operation: Air carrier
- Aircraft: [N699BR](https://openairdocs.org/aircraft/N699BR), registered now
- Make and model: Cndair CL6002B19
- Aircraft serial: 7801
- Aircraft time: 21,860 hours, 17,858 cycles
- System (JASC): [2150 · Cabin Cooling System](https://openairdocs.org/jasc/2150)
- Part: Sensor
- Condition: Malfunctioned
- Location: Ac Bay
- Stage of operation: UK
- How discovered: O
- Nature of condition: B
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA201230095

## Discrepancy

LEFT PACK OVERTEMP SMOKE FROM GASPER FANS.  (FLT 5670)  REPLACED LEFT PACK TEMPERATURE SENSOR, THE LEFT PACK, AND THE LEFT DUAL BYPASS VALVE.  PN: 782790-15  SN: OFF 200010194, PN: 808440-2  SN: 200303025

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.