# SDR SWIA201440085

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: October 20, 2014
- Submitted: November 24, 2014
- Operation: Air carrier
- Aircraft: N603QX
- Make and model: Cndair CL6002C10
- Aircraft serial: 10011
- Aircraft time: 33,548 hours, 24,475 cycles
- System (JASC): [2497 · Electrical Power System Wiring](https://openairdocs.org/jasc/2497)
- Part: Insulation
- Condition: Torn
- Location: Feeder Cable
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA201440085

## Discrepancy

NR 2 ENGINE IDG ELECTRICAL POWER LEAD CABLES PROTECTIVE SHEATHING TORN IN MULTIPLE LOCATIONS FROM IDG TO PYLON.  C-CHECK, REPAIRED NR 2 ENG IDG ELECTRICAL POWER LEAD CABLES INSULATING JACKET AT REQUIRED LOCATIONS IAW REO.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.