# SDR SWIA201642258

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: May 22, 2016
- Submitted: June 24, 2016
- Operation: Air carrier
- Aircraft: [N817SK](https://openairdocs.org/aircraft/N817SK), registered now
- Make and model: Cndair CL6002D24
- Aircraft serial: 15107
- Aircraft time: 25,693 hours, 16,050 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Intercostal
- Condition: Corroded
- Location: Fuselage
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA201642258

## Discrepancy

CORROSION ON INTERCOSTAL AT STR 27R  BETWEEN FS364.00 AND FS349.00.  REMOVED AND INSTALLED INTERCOSTAL AT STR 27R BETWEEN FS 364.00 AND FS 349.00 IAW SRM.  PERFORMED PRESSURE CHECK.  PRESSURE CHECK GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.