# SDR SWIA2020042750327

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 12, 2020
- Submitted: April 27, 2020
- Operation: Air carrier
- Aircraft: [N805SK](https://openairdocs.org/aircraft/N805SK), registered now
- Make and model: Cndair CL6002D24
- Aircraft serial: 15069
- Aircraft time: 35,140 hours, 21,974 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Door Sill
- Condition: Corroded
- Location: Fuselage
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA2020042750327

## Discrepancy

R/H FLOOR SILL AT F.S. 295.00 TO F.S. 310.00 IS CORRODED AROUND FASTENER HOLES.   (C-CHECK) RO 4/23/2020   REPLACED NEW R/H FLOOR SILL AT F.S. 295.00 TO F.S. 310.00 REF CRJ-900 SRM AND DWG. PARTS REPLACED WITH OEM, NO WEIGHT CHANGE NOTED. COMPLIED WITH SKYWEST TASK CARD FOR MAJOR REPAIR. COMPLIED WITH MX FORM 337.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.