## Discrepancy

RT SIDE FLOOR SILL FROM FS 280 TO FS 319.70 HAS AREAS OF CORROSION, MARKED.  C-CHECK RO 9/5/2020.  RT FLOOR SILL FROM FS 280.00 TO FS 319.70 REPLACED, REF CRJ700 SRM DWG.  COMPLIED WITH TASKCARD.  PRESSURIZATION LEAK CHECK GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.