# SDR SWIA202054794

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 4, 2020
- Submitted: December 30, 2020
- Operation: Air carrier
- Aircraft: [N802SK](https://openairdocs.org/aircraft/N802SK), registered now
- Make and model: Cndair CL6002D24
- Aircraft serial: 15061
- Aircraft time: 36,533 hours, 23,029 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Floor Support
- Condition: Corroded
- Location: Pressure Deck
- Stage of operation: IN
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA202054794

## Discrepancy

CORROSION ON RT PRESSURE FLOOR SILL DOUBLER AT FS 797.00, AREAS MARKED.  C-CHECK RO 12/26/2020.  REMOVED CORROSION FROM RT PRESSURE FLOOR SILL DOUBLER AT FS 797 REFERENCING CRJ 900 SRM.  REPAIRED RT PRESSURE FLOOR SILL DOUBLER REFERENCING REO 690-53-41-246 REVISION DATED 2020-11-27.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.