# SDR SWIA202055105

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: October 25, 2020
- Submitted: January 8, 2021
- Operation: Air carrier
- Aircraft: [N609SK](https://openairdocs.org/aircraft/N609SK), registered now
- Make and model: Cndair CL6002C10
- Aircraft serial: 10020
- Aircraft time: 42,111 hours, 31,503 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Door Sill
- Part number: SH670319861
- Condition: Corroded
- Location: Zone 200
- Stage of operation: IN
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA202055105

## Discrepancy

GALLEY SERVICE DOOR SURROUND STRUCTURE: LOWER MOUNTING ANGLE FOR FLOOR SUPPORT IS CORRODED, MARKED.  C-CHECK RO 1/5/2021.  REMOVED AND INSTALLED NEW GALLEY SERVICCE DOOR SURROUND STRUCTURE LOWER FLOOR SUPPORT MOUNT ANGLE, REF CRJ 900 SRM 51-42-06-001-001-A01, 51-42-21-001-001-A01, DWG SH670-31996 REV NC AND DWG SH670-31986 REV NC.  COMPLIED WITH 51-900-1002-SKY.  COMPLETED FORM M-337.  PERFORMED LEAK CHECK, NO LEAKS NOTED.  SEE CONTINUATION CARD FOR DETAILS.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.