# SDR SWIA202055411

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 23, 2020
- Submitted: January 19, 2021
- Operation: Air carrier
- Aircraft: N868AS
- Make and model: Cndair CL6002B19
- Aircraft serial: 7474
- Aircraft time: 40,854 hours, 38,316 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Floor Support
- Condition: Corroded
- Location: Zone 200
- Stage of operation: IN
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA202055411

## Discrepancy

THE RBL 9.0 FLOOR-SUPPORT BEAMS CAP HAS CORROSION ALONG ITS ENTIRE LENGTH, FROM APPROXIMATELY FS 409+128 TO APPROXIMATELY FS 559, THE CORROSION IS ON BOTH THE INBOARD AND OUTBOARD FLANGES, AND EXTENDS UNDER THE FLOOR BEAM SEAT RAILS (MARKED WITH RED GREASE PENCIL).  C-CHECK RO 1/16/2021.  CUT OUT DAMAGED FLOOR BEAM AND BEAM FLANGES AT RBL 9, APPROXIMATELY FS 409128 TO FS 559.0.  FABRICATED & INSTALLED NEW FLOOR BEAM SECTION, SPLICE PARTS & C- CHANNELS, AS PER REO 601R-53-41-2824 REV -, DATED 2020-12-06, DRAWING 601R31025 REV F AND CRJ 200 SRM'S 51-42-06, 51-42-21.  INSTALLED USING NEW NUT CLIPS , DOME NUTS & FASTENERS. PRESSURE LEACK CHECKS GOOD. SEE CONTINUE CARDS FOR DETAILS. COMPLIED WITH 51-900-1003-SKY.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.