# SDR SWIA202055422

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 24, 2020
- Submitted: January 19, 2021
- Operation: Air carrier
- Aircraft: N868AS
- Make and model: Cndair CL6002B19
- Aircraft serial: 7474
- Aircraft time: 40,854 hours, 38,316 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Floor Support
- Condition: Corroded
- Location: Zone 200
- Stage of operation: IN
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA202055422

## Discrepancy

RIGHT FLOOR SILL HAS MULTIPLE AREAS OF CORROSION FS 409.00+72-FS 409.00+128, MARKED.  C-CHECK RO 1/16/2021.  REMOVED HEAVY COROSION FROM MULTIPLE AREAS OF RT FLOOR SILL PANEL BETWEEN FS 409+72 & FS 409+128, REF CRJ200 SRM 51-21-06.  EVALUATED AND FOUND BLENDED OUT WITHIN LIMITS, NDT NO DEFECTS NOTED, REF REO 601R-53-31-1161, REV-, 2020-12-13, RT FLOOR SILL FS 409+72 TO FS 409+128.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.