# SDR SWIA202056024

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 21, 2020
- Submitted: February 9, 2021
- Operation: Air carrier
- Aircraft: [N708SK](https://openairdocs.org/aircraft/N708SK), registered now
- Make and model: Cndair CL6002C10
- Aircraft serial: 10156
- Aircraft time: 44,696 hours, 28,780 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Floor Support
- Condition: Corroded
- Location: Zone 200
- Stage of operation: IN
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA202056024

## Discrepancy

AFT CARGO FS1015-1030 R/H FLOOR SILL IS CORRODED (MARKED WITH RED)   (C-CHECK) RO 2/6/2021   REMOVED CORROSION ON RH FLOOR SILL BETWEEN FS1015 AND FS1030.  REF CRJ700 SRM 51-21-06-001-001-A01.  NDT DEFECT FREE.  EVAL OF MATERIAL REMOVED FOUND TO BE OUT OF LIMITS.  REF CRJ SRM 53-00-45-001-001-A01.  REMOVED AND REPLACED WITH NEW FLOOR SILL.  REF CRJ700 SRM 51-42-06-001-001-A01 AND DWG MM670-35052 REV K.  LEAK CHECK OF REPAIRED AREA GOOD.  COMPLIED WITH TASK CARD 51-900-1002-SKY (CL600-2C10) STRUCTURAL REPAIR (**RII**)

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.