# SDR SWIA202157502

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 10, 2021
- Submitted: April 14, 2021
- Operation: Air carrier
- Aircraft: [N908EV](https://openairdocs.org/aircraft/N908EV), registered now
- Make and model: Cndair CL6002B19
- Aircraft serial: 7654
- Aircraft time: 39,055 hours, 36,450 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Floor Support
- Condition: Corroded
- Location: Bs 409-559
- Stage of operation: IN
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA202157502

## Discrepancy

LH PRESSURE FLOOR SILL HAS MULTIPLE SPOTS OF CORROSION FROM F.S. 409.00+128 TO F.S. 559.00     (C-CHECK RO 4/12/2021)    REPAIRED LH PRESSURE SILL FROM FS409+128 TO FS559 IAW REO 601R-53-41-666 REV-C DATED 2012-11-06. COMPLETED TASK CARD 51-900-1003-SKY AND ATTACHED COMPLETED FORM 337.NO WEIGHT CHANGE.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.