# SDR SWIA202157682

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 20, 2021
- Submitted: April 23, 2021
- Operation: Air carrier
- Aircraft: [N611SK](https://openairdocs.org/aircraft/N611SK), registered now
- Make and model: Cndair CL6002C10
- Aircraft serial: 10035
- Aircraft time: 43,046 hours, 31,760 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Protector
- Condition: Corroded
- Location: Door Sill
- Stage of operation: IN
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA202157682

## Discrepancy

WEB FLOOR PROTECTOR FOUND CORRODED ON SERVICE DOOR SILL MIDDLE AFT P/N SH670-32040-2     (C-CHECK RO 4/21/2021)    REMOVED CORROSION ON MIDDLE AFT WEB FLOOR PROTECTOR ON SERVICE DOOR LOWER SILL REF CRJ700 SRM 51-21-06-001-001-A01. FOUND TO BE OUT OF LIMITS. REMOVED AND INSTALLED NEW WEB FLOOR PROTECTOR ON SERVICE DOOR SILL P/N SH670-32040-4 REF CRJ700 SRM 51-42-06-001-001-A01 AND DWH SH670-31950 REV-Y. COMPLIED WITH TASK CARD 51-900-1002-SKY. SEE CONTINUE CARD FOR DETAILS.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.