# SDR SWIA202159936

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: May 22, 2021
- Submitted: August 2, 2021
- Operation: Air carrier
- Aircraft: [N806SK](https://openairdocs.org/aircraft/N806SK), registered now
- Make and model: Cndair CL6002D24
- Aircraft serial: 15070
- Aircraft time: 37,109 hours, 23,528 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Door Sill
- Condition: Corroded
- Location: Galley Door Area
- Stage of operation: IN
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA202159936

## Discrepancy

* R/H FS 319 - 349 GALLEY SERVICE DOOR CUT-OUT SILL ANGLE HAS CORROSION ALONG IT.      (C-CHECK RO 7/28/2021)    REMOVED AND REPLACED SERVICE DOOR CUT-OUT SILL ANGLE P/N SH670-31996-3S. REF. CRJ900 SRM 51-42-06-001-001-A01 AND DWG# SH670-31950 REV. Y SHEET 8. / COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY (CL600-2D24) STRUCTURAL MAJOR REPAIR (**RII**)

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.