# SDR SWIA202401290006

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: January 26, 2024
- Submitted: January 29, 2024
- Operation: Air carrier
- Aircraft: [N604SK](https://openairdocs.org/aircraft/N604SK), registered now
- Make and model: Cndair CL6002C10
- Aircraft serial: 10249
- Aircraft time: 40,475 hours, 30,980 cycles
- System (JASC): [3040 · Windshield/Door Rain/Ice Removal](https://openairdocs.org/jasc/3040)
- Part: Heater
- Condition: Warning Message
- Location: R Window
- Stage of operation: IN
- How discovered: O
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA202401290006

## Discrepancy

AT NEXT MX OPPORTUNITY TROUBLESHOOT R WINDOW HEAT CAUTION DUE TO REPEAT WRITE UPS MCI TYPE: TROUBLESHOOTING PRIORITY 1 (FILED CLOSED)REMOVED AND REPLACED R COCKPIT WINDOW IN REFERENCE TO CRJ 700 AMM 56-12-01 AND COMPLIED WITH TASK CARD 56-220-1000-SKY. PERFORMED OPS TEST OF THE WINDSHIELD/SIDE WINDOW TEMPERATURE CONTROLLER IN REFERENCE TO CRJ 700 AMM 30-41-06 AND PERFORMED PRESSURIZATION LEAK CHECK IN REFERENCE TO CRJ 700 AMM 21-31-00. OPS CHECK AND LEAK CHECK GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.