# SDR SWIA2024081900717

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 17, 2024
- Submitted: August 19, 2024
- Operation: Air carrier
- Aircraft: [N113SY](https://openairdocs.org/aircraft/N113SY), registered now
- Make and model: Emb ERJ 170-200 LR
- Registry model: [EMB ERJ 170-200 LR](https://openairdocs.org/model/embraer-s-a-erj-170-200-lr) (OpenAirDocs)
- Aircraft serial: 17000407
- Aircraft time: 26,550 hours, 15,238 cycles
- System (JASC): [5315 · Fuselage Main, Floor Beam](https://openairdocs.org/jasc/5315)
- Part: Floorbeam
- Condition: Corroded
- Location: Zone 200
- Stage of operation: IN
- How discovered: O
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA2024081900717

## Discrepancy

AFT WET AREA FLOOR STRUCTURE HAS CORROSION ON RH I/B BEAM AT FR 87 AS MARKED.     (C-CHECK RO 8/19/2024)    REMOVED AND REPLACED AFT WET AREA FLOOR STRUCTURE RH I/B BEAM AT FR 87 REF. EMB SRM 51-40-08

---