# SDR SWIA2025122375817

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 23, 2025
- Submitted: April 20, 2026
- Operation: Air carrier
- Aircraft: [N941SW](https://openairdocs.org/aircraft/N941SW), registered now
- Make and model: Cndair CL6002B19
- Aircraft serial: 7750
- Aircraft time: 43,867 hours, 37,231 cycles
- System (JASC): [5315 · Fuselage Main, Floor Beam](https://openairdocs.org/jasc/5315)
- Part: Floorbeam
- Condition: Corroded
- Location: Zone 200
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA2025122375817

## Discrepancy

FLOOR BOARD SUPPORT STRAP AT APPROX. FS.559.00 BETWEEN RBL9 AND RBL36 HAS MULTIPLE SPOTS OF CORROSION (MARKED).   REPLACED FLOORBOARD SUPPORT STRAP AT FS.559.00 BETWEEN RBL9 AND RBL36 REF. DWG 601R31025 REV. N, CRJ200 SRM 51-42-06-00, AND CRJ200 SRM 51-42-15-00. LEAK CHECK GOOD.COMPLIED WITH SKYWEST TASK CARD 51-900-1003-SKY

---