# SDR SWIA2026012000013

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: January 13, 2026
- Submitted: January 20, 2026
- Operation: Air carrier
- Aircraft: [N794SK](https://openairdocs.org/aircraft/N794SK), registered now
- Make and model: Cndair CL6002C10
- Aircraft serial: 10298
- Aircraft time: 38,326 hours, 25,225 cycles
- System (JASC): [2613 · Overheat Detection](https://openairdocs.org/jasc/2613)
- Part: Overheat Loop
- Condition: Faulted
- Stage of operation: CL
- How discovered: O
- Nature of condition: N
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA2026012000013

## Discrepancy

ANTI ICE DUCT WARNING ON CLIMB OUT OF DEN. QHR CLEARED THE MSG AND WE DIDNÂ€™T NEED TO USE THE ANTI ICE AFTER THAT.  (FLIGHT 5366)  INTERROGATED MDC AND FOUND B1 CODES 007309 (L WING LOOP B) AND 007180 (L BLEED LOOP A).  TROUBLESHOT L BLEED LOOP A PER FIM 36-21-01-810-801. USING BREAKOUT BOX TESTED RESISTANCE TO L BLEED LOOP A AND RECORDED RESISTANCE SLIGHTLY HIGHER THAN NOMINAL VALUE BUT NOT TWICE NOMINAL VALUE. TAPPED ON ALL ASSOCIATED CONNECTIONS AND MOVED BLEED LOOPS AROUND IN ORDER TO TRY TO SEE A JUMP IN VALUES. NO JUMP IN RESISTANCE VALUES NOTED AT THIS TIME. HOWEVER, DURING INSPECTION OF CONNECTIONS NOTICED THAT CONNECTOR MT137 APPEARED EXCESSIVELY BACKED OFF AND ONCE SAFETY CABLE WAS CUT COULD BE LOOSENED BY HAND. CLEANED CONNECTION AND REPLACED CERAMIC INSERT AT CONNECTION POINT MT137 PER AMM 36-21-00 AND RECONNECTED AND PROPERLY TORQUED CONNECTION PER AMM 36-21-00. UPON INITIAL ARRIVAL TO AC DUCT MON FAULT WAS POSTED HARD FAULTED. UPON POWERING UP AC AFTER WORK WAS ACCOMPLISHED, DUCT MON FAULT MESSAGE NO LONGER POSTED. PER

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.