# SDR SWIA2026030675426

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 13, 2026
- Submitted: March 6, 2026
- Operation: Air carrier
- Aircraft: [N140SY](https://openairdocs.org/aircraft/N140SY), registered now
- Make and model: Emb ERJ 170-200 LR
- Registry model: [EMB ERJ 170-200 LR](https://openairdocs.org/model/embraer-s-a-erj-170-200-lr) (OpenAirDocs)
- Aircraft serial: 17000470
- Aircraft time: 27,678 hours, 16,509 cycles
- System (JASC): [5330 · Fuselage Main, Plate/Skin](https://openairdocs.org/jasc/5330)
- Part: Skin
- Condition: Dented
- Location: Zone 100
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA2026030675426

## Discrepancy

DENT IN OUTER SKIN LOCATED 2"AFT OF FRAME 99 AND 1.125" INBOARD STRINGER 29L. DENT IS 1.010" WIDTH AND 1.043" LENGTH. HEIGHT IS .015".     (C-CHECK RO 03/05/2026)PERFORMED PERMANENT DOUBLER AND FILLER REPAIR AT FR 99 STGR 29L - 29R REF ETD2026-170-003204. SEE CONTINUATION CARD FOR WORK ACCOMPLISHED. NO CHANGE TO WEIGHT AND BALANCE. EXTERNAL DET (DETAILED VISUAL INSPECTION): INSPECTION THRESHOLD 20000 FC OR 26600 FH WHICHEVER OCCURS FIRST, INSPECTION INTERVAL 10000 FC OR 13300 FH WHICHEVER OCCURS FIRST.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.