# SDR SWIA2026060876766

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 8, 2026
- Submitted: August 12, 2026
- Operation: Air carrier
- Aircraft: [N719SK](https://openairdocs.org/aircraft/N719SK), registered now
- Make and model: Cndair CL6002C10
- Aircraft serial: 10188
- Aircraft time: 53,940 hours, 36,637 cycles
- System (JASC): [5310 · Fuselage Main, Structure](https://openairdocs.org/jasc/5310)
- Part: Ground Stud
- Part number: SH670318913
- Condition: Corroded
- Location: Zone 100
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA2026060876766

## Discrepancy

A-BAY FRAME AT FS 319, STR 18L HAD TWO CORRODED GROUNDING STUDS & HARDWARE.  REMOVED AND INSTALLED NEW A-BAY FRAME AT BS 319 BTWN STR 18L & STR 21L IAW SRM 51-42-06-001-001-A01,  SRM 51-42-21-001-001-A01, AND DWG SH670-31810, REV AE. PERFORMED PRESSURE LEAK TEST OF THE REPAIR AREA IAW AMM 21-31-00-910-801-A01. LEAK TESTED GOOD. COMPLIED WITH TASK CARD 51-900-1002-SKY. SEE CONTINUE CARD FOR WORK PERFORMED.

---