# SDR SWIA2026090277099

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: September 2, 2026
- Submitted: September 4, 2026
- Operation: Air carrier
- Aircraft: [N719SK](https://openairdocs.org/aircraft/N719SK), registered now
- Make and model: Cndair CL6002C10
- Aircraft serial: 10188
- Aircraft time: 53,968 hours, 36,656 cycles
- System (JASC): [2121 · Air Distribution Fan](https://openairdocs.org/jasc/2121)
- Part: Fan
- Part number: GG670950227
- Part serial: 01200
- Condition: Odor
- Location: Zone 900
- Part time: 27,437 hours, 19,215 cycles
- Stage of operation: NR
- How discovered: O
- Nature of condition: B
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA2026090277099

## Discrepancy

STRONG ELECTRICAL ODOR NEAR GALLEY & ODOR CONTINUES THROUGH ACFT. (FLIGHT 4953) ON ARRIVAL TO ACFT, NO BURNING OR ELECTRICAL ODORS NOTED. PERFORMED OPS CHKS OF LT & RT PACKS WITH APU & LT & RT ENGS IAW AMM 21-50-00, BOTH INDEPENDENTLY & WITH ALL 3 IN OPERATION. UNABLE TO REPRODUCE BURNING OR ELECTRICAL ODOR. TROUBLESHOT IAW FIM 21-22-00-810-806. NOTED LOW AIR VOLUME FROM GALLEY EXHAUST FAN R & R GALLEY EXHAUST FAN IAW AMM 21-23-93. OPS CHKD GOOD.  PERFORMED LEAK CHK OF EXHAUST DUCTS IAW AMM 21-23-00. LEAK CHKD GOOD. INSPECTED RECIRC FAN NR 1 & NOTED DEBRIS ACCUMULATED AROUND RECIRC FILTER. R & R RECIRC FAN, NR 1 FILTER IAW AMM 21-22-12. OPS CHKD GOOD.  LEAK CHKD GOOD.  DUE TO HISTORY OF RECIRC FAN 1 FAULT MSGS, R & R RECIRC FAN 1 IAW  AMM 21-22-10. OPS CHKD GOOD. PERFORMED LEAK CHK DISTRIBUTION SYS BELOW CARGO BAY FLOOR IAW AMM 21-20-00.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.