# SDR SWIA2026100877554

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: October 8, 2026
- Submitted: October 17, 2026
- Operation: Air carrier
- Aircraft: [N919EV](https://openairdocs.org/aircraft/N919EV), registered now
- Make and model: Cndair CL6002B19
- Aircraft serial: 7780
- Aircraft time: 41,124 hours, 42,091 cycles
- System (JASC): [2910 · Hydraulic System, Main](https://openairdocs.org/jasc/2910)
- Part: Hydraulic Line
- Condition: Failed
- Location: Zone 100
- Stage of operation: CL
- How discovered: O
- Nature of condition: K, J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/SWIA2026100877554

## Discrepancy

HYD 1 LO PRESS  ON CLIMB OUT, RAN QRH DID NOT FIX ISSUE, HAD TO TURN PUMP OFF, SHOWED 600 PSI & ZERO FLUID QTY.  FLIGHT 5133.   REF AML 202066 FOR ED1 R & R, REF AML 2011651 FOR ENGINE DRIVEN PUMP EDP AFTER DRY OPS DUE TO HYDRAULIC FLUID LOSS COMPLIANCE,  REF AML 2011616 FOR HYD LINE PRESSURE & CASE DRAIN R & R, & FIX,  REF AML 2012068 FOR ED1 OPS CHECK & LEAK CHECK.  HYD 1 SYS WITHIN LIMITS & OPS CHKD GOOD IAW AMM 29-10-00. OPS CHECK GOOD, NO LEAKS NOTED, NO MESSAGES NOTED.

---