# SDR TRBA2008019

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 13, 2008
- Submitted: February 21, 2008
- Operation: Air carrier
- Aircraft: [N417AT](https://openairdocs.org/aircraft/N417AT), registered now
- Make and model: Aerosp ATR 72-212
- Registry model: [Aerosp ATR 72-212](https://openairdocs.org/model/aerospatiale-atr-72-212) (OpenAirDocs)
- Aircraft serial: 417
- Aircraft time: 26,425 hours, 24,881 cycles
- System (JASC): [2497 · Electrical Power System Wiring](https://openairdocs.org/jasc/2497)
- Part: Wire
- Part number: E0261CF202224
- Condition: Burned
- Location: Cockpit
- Stage of operation: CR
- How discovered: O
- Nature of condition: B, J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/TRBA2008019

## Discrepancy

EMERGENCY BATTERY FAULT IN FLIGHT AND ELECTRICAL BURNED ODOR IN COCKPIT.  AFTER A RESET IT CAME BACK ON. ALSO A FAULT ON THE AVIONICS VENT CAME ON SHORTLY AFTER.   REPAIRED VARIOUS WIRES OF THE EMERGENCY BATTERY CHARGE SYSTEM IAW JIC 20-27-17 AND  PERFORMED OPT CK IAW JIC 24-31-85. PERFORMED OPT CK OF AVIONICS VENT VALVE IAW JIC 21-23-00.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.