# SDR TRBA201208601

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 23, 2012
- Submitted: March 26, 2012
- Operation: Air carrier
- Aircraft: N342AT
- Make and model: Aerosp ATR 72-212
- Registry model: [Aerosp ATR 72-212](https://openairdocs.org/model/aerospatiale-atr-72-212) (OpenAirDocs)
- Aircraft serial: 345
- Aircraft time: 36,650 hours, 36,429 cycles
- System (JASC): [3350 · Emergency Lighting](https://openairdocs.org/jasc/3350)
- Part: Power Supply
- Part number: 3012000
- Part serial: 186
- Condition: Inoperative
- Location: Emergency Light
- Stage of operation: TX
- How discovered: C
- Nature of condition: L
- Precautionary procedure: D
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/TRBA201208601

## Discrepancy

FLIGHT 4820, CREW REPORTED THAT HALF OF AISLE EVACUATION LIGHTS ON REAR HALF OF CABIN INOPERATIVE.  ACFT REMOVED FROM SERVICE.  R & R EMERGENCY LIGHT POWER SUPPLY FIN 73WL AS PER JIC 33-51-21.  PERFORMED OPS CHECK FOUND WORKING PROPERLY IAW W/C EX-335000-OPT-10000-001. ACFT RETURNED TO SERVICE.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.