# SDR TWAA0103501

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 22, 2001
- Submitted: February 23, 2001
- Operation: Air carrier
- Aircraft: N9302B
- Make and model: Doug DC-9-83
- Registry model: [Doug DC-9-83](https://openairdocs.org/model/douglas-dc-9-83) (OpenAirDocs)
- Aircraft serial: 49528
- Aircraft time: 42,726 hours, 21,393 cycles
- System (JASC): [2170 · Humidity Control System](https://openairdocs.org/jasc/2170)
- Part: Separator
- Part number: 17946081
- Condition: Contaminated
- Location: Ac Bay
- Stage of operation: LD
- How discovered: V
- Nature of condition: B
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/TWAA0103501

## Discrepancy

CABIN ATTENDANTS REPORTED SMOKE IN CABIN ON LANDING.  BOTH PACKS AND ENGINE AND AIRFOIL ANTI-ICE ON.  PERFORMED PACK BURN OUT, RESET PINS ON LT HOT AIR VALVE, AND REPLACED THE WATER SEPARATORS.  CHECK-C 10-16-00 STL.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.