# SDR TWAA9786002

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 30, 1997
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: N982PS
- Make and model: Doug DC-9-31
- Registry model: [Doug DC-9-31](https://openairdocs.org/model/douglas-dc-9-31) (OpenAirDocs)
- Aircraft serial: 47251
- System (JASC): [3350 · Emergency Lighting](https://openairdocs.org/jasc/3350)
- Part: Power Supply
- Part number: 582222
- Condition: Inoperative
- Location: Cabin
- Stage of operation: CR
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/TWAA9786002

## Discrepancy

STL - FLT 120 - DURING CRUISE, EGRESS LIGHT ILLUMINATED INTERMITTENTLY.  REMOVED AND REPLACED POWER SUPPLY, MFG PN 5822-22, MANUFACTURED BY LUMINESCENT SYSTEMS, INC.  OPS CHECK NORMAL.  CHECK C - 1-22-97 - STL.  (X)

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.