# SDR UALA2008121606910

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 16, 2008
- Submitted: December 17, 2008
- Operation: Air carrier
- Aircraft: [N662UA](https://openairdocs.org/aircraft/N662UA), registered now
- Make and model: Boeing 767322
- Aircraft serial: 27159
- Aircraft time: 67,960 hours, 11,028 cycles
- Engine: Pwa PW4060
- System (JASC): [2150 · Cabin Cooling System](https://openairdocs.org/jasc/2150)
- Part: Control Valve
- Part number: 3964622
- Condition: Inoperative
- Location: Rt Ac Pack
- Stage of operation: IN
- How discovered: O
- Nature of condition: J
- Precautionary procedure: D
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UALA2008121606910

## Discrepancy

RIGHT PACK OFF LIGHT NOT ILLUMINATED WITH PACK OFF.  REPLACED FLOW CONTROL CARD, NO HELP.  FOUND FLOW CONTROL VALVE INOP.  REPLACED RT PACK FLOW CONTROL VALVE.  OP CHECK GOOD.

---