## Discrepancy

FQTY RT MAIN DISPLAY BLANK.  RELAY RT CTR FUEL PUMP INHIBIT IN P210 IS NOT IN COMMANDED POSITION.  ACTIVE MESSAGE 28-12017. DID STEPS A&B FIM 28-22 TASK 839, NO HELP.   REPLACED RH #17 TANK UNIT, AND LH #14, BITE CHK GOOD.

---