## Discrepancy

CHRONIC LT CTR TANK FUEL PUMP FAULT RELATED TO MESSAGE.  REPLACED CONNECTOR D2189P, WIRE W8189-2001R-20, WIRE W8189-2001B-20, AND CONNECTOR DS28110.   INSTALLED NEW PRESSURE SWITCH INW IPC 28-42-01-002 ITEM 22 ACP TEST OF LT CTR FUEL PUMP PRESSURE SWITCH S28110 PER MM.

---