# SDR UALA2011040401611

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: April 2, 2011
- Submitted: April 27, 2011
- Operation: Air carrier
- Aircraft: [N652UA](https://openairdocs.org/aircraft/N652UA), registered now
- Make and model: Boeing 767322
- Aircraft serial: 25390
- Aircraft time: 81,476 hours, 13,116 cycles
- Engine: Pwa PW4060
- System (JASC): [2820 · Aircraft Fuel Distribution System](https://openairdocs.org/jasc/2820)
- Part: Pressure Sensor
- Part number: 7G1018600U
- Part serial: 35
- Condition: Failed
- Location: Fuel System
- Stage of operation: IN
- How discovered: O
- Nature of condition: O
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UALA2011040401611

## Discrepancy

L FUEL OVERRIDE PUMP CIRCUIT BREAKER IS OUT.  MEL COMPLIANT.  REPLACED LEFT OVERRIDE PUMP PER AMM.  NO PUMP PRESSURE.  CHECKED PRESSURE SWITCH, OVERRIDE PUMP FOUND FAILED.  REPLACED PCN AS PER MM.  OP'S NORMAL NOW.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.