## Discrepancy

'RT PACK INOPERATIVE' LIGHT ON.  EICAS MESSAGE 'RT PACK TEMP' DISPLAYED.  OPERATED NORM AFTER 'STANBY' SELECTED.   RIGHT PACK CONTROLLER 'RAM INLET ACTUATOR', 'LOW LIMIT VALVE' & 'COMPRESSOR SENSOR'.  REPLACED RIGHT PACK CONTROLLER.  BITE TESTED OKAY.

---