# SDR UALA2012103006249

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: October 30, 2012
- Submitted: December 3, 2012
- Operation: Air carrier
- Aircraft: [N206UA](https://openairdocs.org/aircraft/N206UA), registered now
- Make and model: Boeing 777222
- Aircraft serial: 30212
- Aircraft time: 59,321 hours, 8,473 cycles
- Engine: Pwa PW40903
- System (JASC): [3810 · Potable Water System](https://openairdocs.org/jasc/3810)
- Part: Cable
- Condition: Out Of Rig
- Location: Water System
- Stage of operation: NR
- How discovered: O
- Nature of condition: O
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UALA2012103006249

## Discrepancy

NO WATER PSI ON A-C CHRONIC PROBLEM.  PER MEL PLACARD 38008 ENSURE POV IS CLOSED.  COMPLIED WITH REQUIREMENTS IN MEL 3810AR.  ADJ- :ADJUSTED RIG OF PRESELECT OVERFLOW VALVE CABLE, OPERATION CHECK NORMAL.  WATER PRESSURE NORMAL IN ALL LAVS AND GALLEY.

---