# SDR UHLA2013011200007

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: January 12, 2013
- Submitted: January 18, 2013
- Operation: Air carrier
- Aircraft: [N862RW](https://openairdocs.org/aircraft/N862RW), registered now
- Make and model: Emb ERJ 170-100 SE
- Registry model: [EMB ERJ 170-100 SE](https://openairdocs.org/model/embraer-erj-170-100-se) (OpenAirDocs)
- Aircraft serial: 17000098
- Aircraft time: 19,650 hours, 11,167 cycles
- System (JASC): [2913 · Hydraulic Pump (Electric/Engine), Main](https://openairdocs.org/jasc/2913)
- Part: Pump
- Condition: Defective
- Location: Hydraulic Sys
- Stage of operation: TO
- How discovered: O
- Nature of condition: K
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UHLA2013011200007

## Discrepancy

HYD 2 LOW QUANTITY AT 0 AND LOSS OF PRESSURE.  DECLARED EMERGENCY, RETURNED TO FIELD, LANDED WITHOUT INCIDENT.  REMOVED AND REPLACED ENGINE DRIVEN HYD PUMP NR 2 IAW AMM 29-11-01.  SERVICED HYD SYSTEM NR 2 IAW AMM 12-12-01.  GROUND RUN AND OPS CHECK NORMAL.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.