# SDR UIEA2013021300079

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 13, 2013
- Submitted: February 14, 2013
- Operation: Air carrier
- Aircraft: [N641GT](https://openairdocs.org/aircraft/N641GT), registered now
- Make and model: Boeing 767-38E
- Registry model: [Boeing 767-38E](https://openairdocs.org/model/boeing-767-38e) (OpenAirDocs)
- Aircraft serial: 25132
- Aircraft time: 69,717 hours, 21,081 cycles
- System (JASC): [2197 · Air Conditioning System Wiring](https://openairdocs.org/jasc/2197)
- Part: Connector
- Condition: Unsecure
- Location: A/C Pack
- Stage of operation: DE
- How discovered: O
- Nature of condition: N
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UIEA2013021300079

## Discrepancy

AT 41000 FT AND START OF DESCENT RT PACK; RT PACK TEMP EICAS MESSAGE, RAN QRH AND PLACED PACK IN STBY MODE.  FOUND CONNECTOR PLUG FOR THE COMPRESSOR OUTLET OVERHEAT TEMP SENSOR VERY LOOSE, RE-SECURED CONNECTOR PLUG IAW AMM 21-51-06, OPS CHECK NORMAL.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.