# SDR UIEA2014070100351

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 1, 2014
- Submitted: August 4, 2014
- Operation: Air carrier
- Aircraft: [N640GT](https://openairdocs.org/aircraft/N640GT), registered now
- Make and model: Boeing 767-3S1
- Registry model: [Boeing 767-3S1](https://openairdocs.org/model/boeing-767-3s1) (OpenAirDocs)
- Aircraft serial: 25221
- Aircraft time: 75,074 hours, 15,819 cycles
- System (JASC): [2421 · AC Generator-Alternator](https://openairdocs.org/jasc/2421)
- Part: Idg
- Condition: Low
- Location: Rt Engine
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UIEA2014070100351

## Discrepancy

STATUS MESSAGE RT IDG VLV.  INSPECTED RT ENG IDG COOLING VLV & PNEU FILTER IAW AMM 24-11-07.  SERVICED IDG IAW AMM 12-13-03, INSPECTED CONNECTOR TO VLV, NOTED NO DEFECT.  ENG RUN NO FAULT PRESENT IAW AMM 71-00-00.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.