# SDR UIEA2017082701552

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: August 26, 2017
- Submitted: August 28, 2017
- Operation: Air carrier
- Aircraft: [N640GT](https://openairdocs.org/aircraft/N640GT), registered now
- Make and model: Boeing 767-3S1
- Registry model: [Boeing 767-3S1](https://openairdocs.org/model/boeing-767-3s1) (OpenAirDocs)
- Aircraft serial: 25221
- Aircraft time: 83,502 hours, 17,710 cycles
- System (JASC): [2897 · Fuel System Wiring](https://openairdocs.org/jasc/2897)
- Part: Connector
- Condition: Dirty
- Location: Fuel Pump
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UIEA2017082701552

## Discrepancy

RIGHT AFT FUEL PUMP TRIPS THE CIRCUIT BREAKER DURING CRUISE.  INSPECTED RT AFT BOOST PUMP CONNECTOR. OK. CLEANED CONNECTOR IAW SWPM 20-10-10.  PERFORM OPEN CHECK IAW AMM 28-22-00-215-154 AND GROUND CHECKED OK.

---