# SDR UIEA2017092001754

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: September 19, 2017
- Submitted: September 21, 2017
- Operation: Air carrier
- Aircraft: [N1181A](https://openairdocs.org/aircraft/N1181A), registered now
- Make and model: Boeing 767-3Y0
- Registry model: [Boeing 767-3Y0](https://openairdocs.org/model/boeing-767-3y0) (OpenAirDocs)
- Aircraft serial: 26206
- Aircraft time: 82,060 hours, 19,910 cycles
- System (JASC): [2160 · Cabin Temperature Control System](https://openairdocs.org/jasc/2160)
- Part: Sensor
- Part number: 6240162
- Part serial: 092C7504
- Condition: Failed
- Location: Cockpit Temp
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UIEA2017092001754

## Discrepancy

FLT DECK TEMP CONTROLLER INOPERATIVE.  BITE CHECKED AUTO CONTROLLER,  FAILED FLT DECK TEMP SENSOR TS175,  REMOVED AND REPLACED THE SENSOR IAW AMM 21-61-02,  OPS CHECKED GOOD .

---