# SDR UIEA2018042700808

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: April 25, 2018
- Submitted: April 27, 2018
- Operation: Air carrier
- Aircraft: [N640GT](https://openairdocs.org/aircraft/N640GT), registered now
- Make and model: Boeing 767-3S1
- Registry model: [Boeing 767-3S1](https://openairdocs.org/model/boeing-767-3s1) (OpenAirDocs)
- Aircraft serial: 25221
- Aircraft time: 85,473 hours, 18,153 cycles
- System (JASC): [2822 · Fuel Boost Pump](https://openairdocs.org/jasc/2822)
- Part: Warning Message
- Condition: False Activation
- Location: Fuel Pump
- Stage of operation: CL
- How discovered: O
- Nature of condition: N
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UIEA2018042700808

## Discrepancy

CENTER RT FUEL PUMP EICAS MESSAGE AFTER TAKEOFF. FOLLOWED QRH PROC 12.16.  RESET THE CIRCUIT BREAKER, PERFORMED AN OPS CHECK IAW 28-22-00 MULTIPLE TIMES, NO DEFECT NOTED, RAN CENTER RT FUEL PUMP FOR 45 MINUTES, NO DEFECTS NOTED, OK FOR SERVICE.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.