# SDR UIEA2018101902286

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: October 19, 2018
- Submitted: October 19, 2018
- Operation: Air carrier
- Aircraft: [N1409A](https://openairdocs.org/aircraft/N1409A), registered now
- Make and model: Boeing 767306
- Aircraft serial: 27960
- Aircraft time: 89,102 hours, 16,724 cycles
- System (JASC): [2163 · Cabin Temperature Sensor](https://openairdocs.org/jasc/2163)
- Part: Filter
- Condition: Clogged
- Location: Temp Sensor
- Stage of operation: CR
- How discovered: O
- Nature of condition: O
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UIEA2018101902286

## Discrepancy

FLT DECK AUTO TEMP CONTROLLER ERRATIC AND UNABLE TO MAINTAIN TEMPERATURE. FOUND FLIGHT COMPARTMENT ZONE TEMP SENSOR FILTER CLOGGED. CLEANED FILTER AND OPS CHECK GOOD IAW AMM 21-61-08-004-003.

---