# SDR UIEA2019061004455

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 7, 2019
- Submitted: June 10, 2019
- Operation: Air carrier
- Aircraft: [N1409A](https://openairdocs.org/aircraft/N1409A), registered now
- Make and model: Boeing 767306
- Aircraft serial: 27960
- Aircraft time: 90,434 hours, 17,178 cycles
- System (JASC): [2160 · Cabin Temperature Control System](https://openairdocs.org/jasc/2160)
- Part: Sensor
- Condition: Faulted
- Location: Duct Temp
- Stage of operation: NR
- How discovered: 9
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UIEA2019061004455

## Discrepancy

FLT DECK DUCT TEMP SENSOR FAULT ON ZONE TEMP CONTROLLER.  REMOVED AND REPLACED FLT DECK DUCT TEMP SENSOR IAW AMM 21-61-02 PERFORMED GOOD OPS CHECK IAW B767 FSM 21-61FAULT TREE 912 NO DEFECTS NOTED.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.