# SDR UIEA2020021740255

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 14, 2020
- Submitted: February 17, 2020
- Operation: Air carrier
- Aircraft: [N640GT](https://openairdocs.org/aircraft/N640GT), registered now
- Make and model: Boeing 767-3S1
- Registry model: [Boeing 767-3S1](https://openairdocs.org/model/boeing-767-3s1) (OpenAirDocs)
- Aircraft serial: 25221
- Aircraft time: 90,354 hours, 19,248 cycles
- System (JASC): [2150 · Cabin Cooling System](https://openairdocs.org/jasc/2150)
- Part: Actuator
- Condition: Faulted
- Location: Rt Pack Inlet
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UIEA2020021740255

## Discrepancy

2 HR  11 MIN INTO FLIGHT AT FL 360, GOT  THE EICAS MESSAGE RIGHT PACK TEMP. MOVED RIGHT PACK CONTROL SELECTOR TO STBY AS PER CHECKLIST AND THE INOP LIGHT WENT OUT.(<P ><SPAN>PERFORMED RIGHT PACK TEMP / CONTROLLER BITE AS PER AMM 21-51-14. THE TEST FAULTED RT PACK INLET / ACTUATOR. RESET AND PERFORMED AUTO TEST PER AMM 21-51-00 AND OPS CHK OK.</SPAN></P>)

---