# SDR UIEA2021031500562

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 14, 2021
- Submitted: March 18, 2021
- Operation: Air carrier
- Aircraft: [N1619A](https://openairdocs.org/aircraft/N1619A), registered now
- Make and model: Boeing 767-3Y0
- Registry model: [Boeing 767-3Y0](https://openairdocs.org/model/boeing-767-3y0) (OpenAirDocs)
- Aircraft serial: 26208
- Aircraft time: 76,237 hours, 13,988 cycles
- System (JASC): [2150 · Cabin Cooling System](https://openairdocs.org/jasc/2150)
- Part: Relay
- Part number: BACR13CD2
- Condition: Malfunctioned
- Location: Exahust Valve
- Stage of operation: TX
- How discovered: O
- Nature of condition: J
- Precautionary procedure: D
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UIEA2021031500562

## Discrepancy

BTB ON PUSHBACK AFTER ENG START FWD EQUP VLV EICAS MSG. RAN QRH LIGHT DID NOT EXT.(<P>TRANSFERRED TO DMI 143825 IAW MEL 21-58-07 PROCEDURE 2. PLACARDS INSTALLED. MCC NOTIFIED. </P><P>LP 1329081: PERFORMED FIM 21-58-58 FT 939. REMOVED AND REPLACED OVERBOARD EXHAUST VALVE INDICATION RELAY IAW SWPM 20-81-22. OPS CHECK GOOD. MCC NOTIFIED. THIS CLEARS DMI 143825. PLAC REMOVED.</P>)

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.