# SDR UIEA2021042500988

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: April 22, 2021
- Submitted: April 26, 2021
- Operation: Air carrier
- Aircraft: [N1487A](https://openairdocs.org/aircraft/N1487A), registered now
- Make and model: Boeing 767-31K
- Registry model: [Boeing 767-31K](https://openairdocs.org/model/boeing-767-31k) (OpenAirDocs)
- Aircraft serial: 28865
- Aircraft time: 89,726 hours, 18,688 cycles
- System (JASC): [2197 · Air Conditioning System Wiring](https://openairdocs.org/jasc/2197)
- Part: Connector
- Part number: R071010A20SN
- Condition: Damaged
- Location: Rt Pack Temp
- Stage of operation: IN
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/UIEA2021042500988

## Discrepancy

FOUND CONNECTOR D10140 ON TS5135 COMP OUTLET TEMP SENSOR 2 BAD BACKSHELL. RH PACK TEMP CONTROL STANDBY MODE SYSTEM INOP TRANSFERRED TO MDDR 145718 IAW DDG 21-51-03-02. CAT C DUE 02MAY21. CONNECTOR D10140 ON TS5135 CAPPED AND STOWED. EH 1346Z. REMOVED AND REPLACED CONNECTOR D10140 ON RIGHT PACK IAW B767 SWPM 20-60-03 TABLE 6. OPS CHECK RIGHT PACK ON STANDBY MODE, OPS CHECKS OK AT THIS TIME. THIS CLEARS MDDR 145718.

---